Arthroscopy
Arthroscopic and sports-medicine fixation: suture anchors, ACL and headless screws, endobuttons and ligament fixation, with an ACL / PCL set.
- Ø 2 to 11 mm
- Anchors · ACL · Herbert screws
- Ti
- ACL / PCL set

Overview
A sports-medicine fixation range of suture anchors, tibial suture discs, endobuttons, ligament washers and staples, and Herbert, ACL, bioabsorbable ACL and headless screws.
Most implants are titanium; the bioabsorbable ACL screws are PLA and β-TCP. An ACL / PCL instrument system supports ligament reconstruction.
At a glance
- Components listed
- 16
- Materials
- Titanium
- Instrument sets
- 1
- Certification
- ISO 9001 · ISO 13485
Components
Specified sizes and materials for every component. Our product specialists can advise on anything not shown.
| Component | Sizes |
|---|---|
| Anchor suture screw | Sizes: Dia 3 mm, 5 mm |
| Anchor suture screw, pre loaded | Sizes: Dia 3 mm, 5 mm |
| Tibial suture disc | Sizes: Hole; slotted |
| Endobutton / loop button | |
| Endobutton with loop | Sizes: Loop size 15, 20, 25, 30 |
| Endobutton with adjustable loop | |
| Multi spiked washer for ligament | Sizes: Spiked 04, 05, 07, 09 |
| Suture post | Sizes: Dia 6.5 mm; length 25, 30, 35 mm |
| Spiked ligament staple | Sizes: Dia 6 mm, 8 mm, 10 mm |
| Herbert screw | Sizes: Dia 3.5/4.5 mm; length 12 to 40 mm (2 mm steps), then 45, 50, 55, 60, 65, 70 mm |
| Herbert screw, colour coded | Sizes: Pink: 2.0/3.0 mm, 12 to 30 mm (2 mm diff). Green: 2.5/3.5 mm, 12 to 40 mm (2 mm diff). Golden: 3.0/4.0 mm, 12 to 40 mm (2 mm diff). Blue: 3.5/4.0 mm, 12 to 70 mm (2 mm diff) |
| A.C.L. screw (anterior cruciate ligament screw) | Sizes: Dia 6, 7, 8, 9, 10, 11 mm; length 15, 20, 25, 30, 35, 40 mm |
| Bio A.C.L. screw, PLA (polylactic acid) | Sizes: Dia 7, 8, 9 mm (24, 30 mm); 10 mm (30 mm); 11 mm (35 mm) |
| Bio A.C.L. screw, B-TCP (B-tricalcium phosphate) | Sizes: Dia 7, 8, 9 mm (24, 30 mm); 10 mm (30 mm); 11 mm (35 mm) |
| Headless screw | Sizes: Dia 2.5 mm: 8 to 30 mm. Dia 3.0, 3.5, 4.0 mm: 12 to 30 mm (2 mm diff) and 30 to 50 mm (5 mm diff). Dia 5.0 mm: 30 to 80 mm (5 mm diff). Dia 6.5 mm: 35 to 100 mm (5 mm diff) |
| ACP / PCL (ACL/PCL) instrument system |
Photos
Scheduling a case with this system?
Share the components, sizes and surgery date. We confirm availability and have the complete set at your hospital before the procedure.
Questions about this system
Answers drawn from this system's own listing.
What is listed in the arthroscopy range?
16 components, each listed with the sizes and materials printed for it.
Which materials is it listed in?
Titanium. The components table shows the material for each line. The choice of material is the surgeon's.
Stainless steel and titanium: an overviewIs an instrument set available?
Yes. One instrument set is listed: ACP / PCL (ACL/PCL) instrument system. Sets are placed at hospitals on consignment.
Sets on consignmentHow do I book this system for a case?
Send four details by phone, WhatsApp or the enquiry form: the implant type; sizes, side and material; surgery date and time; hospital and surgeon. Please do not send patient details.
Book a setIs the system certified?
All products supplied by Eliix are certified under ISO 9001:2015 and ISO 13485:2016.
Certification