Skip to content

Stainless steel and titanium in orthopaedic implants: a buyer's overview

How implant-grade stainless steel and titanium differ in composition, properties and labelling. A neutral overview for procurement teams.

For hospital procurement teams · 4 min read · General information, not medical advice

Two families of metal

Most plates, screws and nails are offered in two materials: stainless steel and titanium. Catalogues print them as SS and Ti. Both are long-established implant materials covered by international standards. They are different metals with different properties, and which one is used for a patient is a clinical decision made by the surgeon.

This overview explains what the two labels mean so that orders, stock lists and invoices can be read correctly. It is not guidance on which material to choose.

What the labels mean

Implant-grade stainless steel and titanium at a glance
PropertyStainless steel (SS)Titanium (Ti)
Typical grade316L, a low-carbon chromium, nickel and molybdenum steelCommercially pure titanium, or the alloy Ti-6Al-4V
Material standardsISO 5832-1, ASTM F138ISO 5832-2 (pure), ISO 5832-3 and ASTM F136 (alloy)
DensityAbout 8.0 g/cm³About 4.4 to 4.5 g/cm³
Stiffness (elastic modulus)About 190 to 200 GPaAbout 105 to 115 GPa
Magnetic behaviourNon-magnetic in the annealed implant gradeNon-magnetic
Usual appearanceBright silverGrey, or coloured by anodising

What follows from the numbers

  • Titanium is a little over half the density of steel, so an implant of the same shape weighs roughly half as much.
  • Titanium is about half as stiff as steel, so a titanium plate of the same shape flexes more under the same load.
  • Titanium implants are often anodised in colours. The colour is a surface oxide used for identification, for example to tell screw diameters apart; it is not a coating of another material.
  • Imaging behaviour and MRI labelling are specific to each device. Rely on the manufacturer's labelling for the implant in question.

Keep one material per construct

Plates and the screws that go through them are normally supplied and used in the same material. A booking should therefore state the material once for the whole construct, and a set should be stocked with matching screws. If a tray holds both materials, they should be clearly separated and labelled.

What to check when ordering

  • The material is stated for every line: SS or Ti.
  • Plates and screws on the same order match.
  • The label on each pack states the material as well as the size and batch number.
  • Where a catalogue lists only one material for an item, the other is not assumed to exist.
  • Other materials are named in full where they apply: PEEK for some spinal cages, UHMWPE for bearing liners.

At Eliix

  • Most plates, nails and screws in the Eliix core trauma range are listed in stainless steel and titanium; each item page shows the options printed for that item.
  • All products are certified under ISO 9001:2015 and ISO 13485:2016.
  • Implants are recorded by size and batch, so the material supplied can be confirmed from the records.

This guide is general information for healthcare professionals and procurement staff. It is not medical advice and does not replace the manufacturer's instructions for use or your hospital's own protocols. See the disclaimer.